Pre-Alert Tone

(Emergency Wide, Man Down)

HGDefinitionPort.jpg

Selects the type of alert tone that sounds once the Pre-Alert Timer has expired. The Pre-Alert Timer begins once the programmed Man Down condition(s) is met (see Man Down Trigger); once this timer period expires, this selected alert tone is sounded.  DotGreen.png This alert tone is also complimented visually with “Man Down” text appearing in the radio's display. DotBlue.png These audible and visual alerts are intended to warn the radio-user that an Emergency Mode is about to be activated, therefore allowing the radio-user to bring the radio into a more vertical position and possibly avoid a false Emergency transmission. This selection applies for both Conventional and Trunking communications.

HGWorkflowNote.jpg

 

To ensure that the radio-user hears this tone even when the radio volume is low, it is recommended to increase the Minimum Volume setting or the Volume Offset (dB) setting.

HGAccessedOnly.jpg

When the radio is model / option capable, and

when the Man Down Trigger field is not set to "Disabled".

HGSelections.jpg

SELECTIONS:

DEFINITIONS:

Single Warning Tone

One tone is sounded at the expiration of the Pre-Alert Timer.

Continuous Warning Tone

A continuous tone is sounded at the expiration of the Pre-Alert Timer and for the duration of the Post-Alert Timer. Therefore, this alert tone ends once the Emergency Mode transmission begins.

GoArrow.jpg

Go to the Man Down Page